8
ALCOVE OR CLOSET REQUIREMENTS
60 in.
2
(387.1 cm
2
)
60 in.
2
(387.1 cm
2
)
1"
(2.5 cm)
15"
(38.1 cm)
1"
(2.5 cm)
5½"
(14 cm)
MINIMUM CLEARANCES
• Dimensions shown are the recommended minimum clearance allowances.
• Space on the sides of the dryer is required to avoid noise transfer.
• Space at the rear of the dryer is necessary to accommodate exhaust ducting.
OTHER REQUIREMENTS
• This dryer must be vented to the outdoors.
• Do not install the dryer in a closet with a solid door.
• A closet door must be louvered or vented with a minimum of 120 sq. in.
(774.2 sq. cm) of opening equally divided at the top and bottom of the door. The
airǍ ow must not be obstructed in any way.
• No other fuel-burning appliance shall be installed in the same closet as the gas
dryer.
ELECTRICAL & GAS SUPPLY REQUIREMENTS
ELECTRIC DRYER (U.S. ONLY)
WARNING
The dryer must be plugged into a properly grounded 3 or 4-wire, single
phase, 120/240 volt (or 120/208 volt), 60Hz, AC-only electrical outlet
connected to an individual 30-amp circuit, fused with a 30-amp
time-delay fuse or circuit breaker. Do not operate a washer and dryer
on the same circuit.
WARNING
This appliance must be grounded. In the event of an electrical short
circuit, grounding reduces the risk of electric shock by providing an
escape route for the electrical current.