Haier CRDE350AW Clothes Dryer User Manual


 
16
A1. Remove the green (neutral) ground wire from the green ground screw located
above the terminal block.
A2. Attach the green power cord ground wire to the cabinet with the green ground
screw. Tighten the screw securely.
A3. Attach the green (neutral) ground wire from the dryer harness and the white
(neutral) power cord wire to the center terminal block screw. Tighten the screw
securely.
A4. Attach each of the remaining 2 power cord wires (red and black) to one of the
outer terminal block screws. Either wire can be attached to either screw. Tighten
both screws securely.
IMPORTANT: Do not make a sharp bend or crimp the wires at connections.
PART B - 3-WIRE POWER CORD
A
B
C
E
F
D
Green Ground Screw
Terminal Block Screw
Outer Power Cord Wires
Power Cord
Center (Neutral) Power Cord Wire
Green (Neutral) Ground Wire
From the Dryer Harness
B1. Attach the center (neutral) power cord wire to the center terminal block screw.
Tighten the screw securely.
B2. Attach each of the remaining 2 power cord wires to one of the outer terminal
block screws. Either wire can be attached to either screw. Tighten both screws
securely.
IMPORTANT: Do not make a sharp bend or crimp the wires at connections.
STEP 2 - CONNECT TO A GAS SUPPLY LINE
(GAS DRYER ONLY)
NOTE: Do not connect the dryer to an LP gas line without nj rst converting the
dyer with a conversion kit. An LP conversion kit must be installed by a qualinj ed
technician.
NOTE: Apply a pipe-joint compound that that is resistant to the action of LP gas to
all males threads. Do not use plumber’s tape.