Graco 24M178 Clothes Dryer User Manual


 
Maintenance and Repair
8 309921N
Pressure Relief Procedure
The following is a basic pressure relief procedure. Be
sure to follow the specific pressure relief procedure in
your spray gun and/or fluid supply equipment manuals.
1. Close the main air shut-off valve.
2. Trigger the gun or dispense valve and open any
drain valves to relieve pressure.
Maintenance and Repair
Air Filter 234402, Series B
To maintain maximum filtering efficiency and avoid
excessive pressure drop, the filter must be kept clean.
See Manual 309919 for cleaning and parts information.
Coalescer 234397, Series B
See Manual 309919 for operation, cleaning, and parts
information.
WARNING
To avoid injury, relieve air and fluid pressure before
checking, cleaning, or repairing the equipment.
Relieve the pressure before cleaning, checking
or repairing. Follow Pressure Relief Proce-
dure, above.
Check system at least once per shift to ensure
proper drainage.
A supply of low flow/low humidity air will pro-
vide longer desiccant life.
NOTE: It is recommended that Air Filter 234402 be
installed upstream of the coalescing filter to
remove 3 micron and larger size particles and sep-
arate large droplets of moisture from the air line.
CAUTION
Never let the liquid level in the bowl reach the base of
the coalescing element.