GE Monogram 49-90152-1 Clothes Dryer User Manual


 
Installation Instructions
27
For 3-wire Connection ONLY:
Be sure the dryer’s green ground wire
is connected to neutral (center) terminal
of block and to green ground screw on
cabinet rear.
D
For 4-wire Connection ONLY:
Remove and discard the dryer’s ground
wire between the cabinet and the center
of the terminal block.
IMPORTANT: Do NOT remove the long
ground wire that runs down inside the
dryer cabinet.
Attach ground wire of power cord to the
cabinet with the green ground screw.
CONNECTING DRYER POWER
CORD (cont.)
For 3-wire and 4-wire Connection: Connect
the neutral (center line on 3-wire, white
line on 4-wire) line to the center of
terminal block.
E
For 3-wire and 4-wire Connection: Tighten
all terminal block screws completely.
CONNECTING DRYER POWER
CORD (cont.)
For 3-wire and 4-wire Connection:
Reinstall the terminal block access cover.
IMPORTANT: Do not leave the access
cover off.
F
G
Ground
Wire
(3-wire Connection Shown)
(4-wire Connection Shown)
(3-wire Connection Shown)
(3-wire Connection Shown)
(3-wire Connection Shown)
Power
Cord
Ground
Wire
Connect
center
screw