GE Monogram 49-90152-1 Clothes Dryer User Manual


 
Install a 1/8” NPT plugged tapping to the
dryer gas line shut-off valve for checking
gas inlet pressure.
Install a flare union adapter to the plugged
tapping.
NOTE: Apply pipe compound or Teflon
®
tape to the threads of the adapter and
plugged tapping.
23
Installation Instructions
Attach the flexible metal gas line
connector to the adapter.
B
Tighten the flexible gas line connection
using two adjustable wrenches.
C
CONNECTING THE DRYER TO THE
GAS SUPPLY (cont.)
D
Tighten all connections using two
adjustable wrenches. Do not overtighten.
E
CONNECTING THE DRYER TO THE
GAS SUPPLY (cont.)
Apply pipe compound or
Teflon
®
tape to all male
threads.
Open the gas shutoff valve.
F
Shut-off Valve
Plugged
Tapping