Frigidaire 137111500B Clothes Dryer User Manual


 
11
Electrical connection (non-Canada) - 3 wire cord
Turn off power supply to outlet. 1.
Remove the screw securing the terminal block access 2.
cover in the lower corner on the back of the dryer.
Install a UL-approved strain relief according to the power 3.
cord/strain relief manufacturer’s instructions in the power
cord entry hole below the access panel. At this time, the
strain relief should be loosely in place.
Thread an UNPLUGGED, UL-approved, 30 amp. power 4.
cord, NEMA 10-30 type SRDT, through the strain relief.
Attach the power cord neutral (center wire) conductor to 5.
the SILVER colored center terminal on the terminal block.
Tighten the screw securely.
Attach the remaining two power cord outer conductors 6.
to the outer, BRASS colored terminals on the terminal
block. Tighten both screws securely.
3-wire receptacle
(NEMA type 10-30R)
Internal ground
Internal ground
(GREEN screw)
(GREEN screw)
Install
Install
UL-approved
UL-approved
strain relief here
strain relief here
Terminal screw
Terminal screw
recovery slot
recovery slot
Line 1
Line 1
(BRASS terminal)
(BRASS terminal)
Neutral
Neutral
(SILVER terminal)
(SILVER terminal)
Line 2
Line 2
(BRASS terminal)
(BRASS terminal)
Access cover
Access cover
screw
screw
Terminal
Terminal
block
block
Neutral
Neutral
(center wire)
(center wire)
30 AMP
30 AMP
NEMA 10-30
NEMA 10-30
Follow manufacturer’s guidelines for fi rmly securing the 7.
strain relief and power cord.
Reinstall the terminal block cover.8.
DO NOT remove
DO NOT remove
internal ground in
internal ground in
a 3-wire system!!
a 3-wire system!!
Neutral
Neutral
terminal
terminal
- ELECTRICAL SHOCK HAZARD - Failure
to disconnect power source before servicing could result in
personal injury or even death.
- ELECTRICAL SHOCK HAZARD - Do not
make a sharp bend or crimp wiring/conductor at connections.
If moving dryer from a 4-wire system and
installing it in a 3-wire system, move the internal ground from
the center terminal back to the GREEN screw next to the
terminal block.
If a terminal screw falls during cord installation, it
can be retrieved in the terminal screw recovery slot below the
access panel.