Installation Instructions
Electrical connection (non-Canada) - 3 wire cord
Turn off power supply to outlet. 1.
Remove the screw securing the terminal block 2.
access cover in the lower corner on the back of
the dryer.
Install a UL-approved strain relief according 3.
to the power cord/strain relief manufacturer’s
instructions in the power cord entry hole below
the access panel. At this time, the strain relief
should be loosely in place.
Thread an UNPLUGGED, UL-approved, 30 amp. 4.
power cord, NEMA 10-30 type SRDT, through the
strain relief.
Attach the power cord neutral (center wire) 5.
conductor to the SILVER colored center
terminal on the terminal block. Tighten the
screw securely.
Attach the remaining two power cord outer 6.
conductors to the outer, BRASS colored
terminals on the terminal block. Tighten both
screws securely.
WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/
conductor at connections.
3-wire receptacle
(NEMA type 10-30R)
Internal ground
Internal ground
(GREEN screw)
(GREEN screw)
Install
Install
UL-approved
UL-approved
strain relief here
strain relief here
Terminal screw
Terminal screw
recovery slot
recovery slot
Line 1
Line 1
(BRASS terminal)
(BRASS terminal)
Neutral
Neutral
(SILVER terminal)
(SILVER terminal)
Line 2
Line 2
(BRASS terminal)
(BRASS terminal)
Access cover
Access cover
screw
screw
Terminal
Terminal
block
block
Neutral
Neutral
(center wire)
(center wire)
30 AMP
30 AMP
NEMA 10-30
NEMA 10-30
NOTE
If a terminal screw falls during cord installation,
it can be retrieved in the terminal screw recovery
slot below the access panel.
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing
could result in personal injury or even death.
Follow manufacturer’s guidelines for fi rmly 7.
securing the strain relief and power cord.
Reinstall the terminal block cover.8.
DO NOT remove
DO NOT remove
internal ground in
internal ground in
a 3-wire system!!
a 3-wire system!!
Neutral
Neutral
terminal
terminal
IMPORTANT
If moving dryer from a 4-wire system and
installing it in a 3-wire system, move the internal
ground from the center terminal back to the