Cissell HF150 Washer User Manual


 
HF234
HF150-185
The machine must be placed on a fl at, solid surface (metal base, concrete
or solid ground). It is recommended that the machine be anchored on the
provided places (A) in the base, especially in case of a plinth
(see Dimensions 2).
The machine must be placed entirely level. For easy maintenance it is re-
commended to keep a minimal distance of 600 mm between the wall and
the back of the machine.
If several machines are placed next to each another, there should be a mi-
nimal distance of 30 mm between each machine.
To prevent damage during transportation, the machine has been equipped
with four red transport brackets to eliminate every possible movement of
the tub.
After the machine has been placed level, take off the service- and the back
panel to remove these transport brackets.
Important
The machine must never be activated before removing
these transport brackets.
Removal of the transport safety
The machine is delivered with hoses with 3/4" connections. These hoses
t the water inlet valves of the machine and the main water inlet taps. To
ensure the optimal functioning of the water inlet valves, the water pres-
sure on the inlet should be between 0,5 and 10 kg/cm² (7 and 145 psi). If
the pressure is too low, the cycle time will increase considerably.
In case of boiler fed machines, a minimum of hot water of 90°C should be
available: For the HF150: 94 l. HF185: 115 l. HF234: 150 l.
Water connection
Installation and connection
3
Ground