Buhler 595 Washer User Manual


 
10
General Instructions and Information
As with any piece of equipment, the care with which your loader is operated and maintained
will greatly affect it’s life and the safety of the people using it.
1. Keep all pivots well lubricated for longer bushing life. Inspect every 500 hours of operation
for wear.
2. Periodically check all bolts for tightness. If any bolt is damaged, replace it with a bolt of
equivalent grade or strength.
3. Follow the recommendations of the tractor manufacturer in regards to the quantity of oil used.
4. Check oil level frequently to ensure the system is full.
5. When making an oil check, be sure lift cylinders are retracted.
6. Before operating the loader, particularly if the loader is left standing for any length of time,
check the hydraulic system and oil level.
7. When installing hydraulics, follow the circuit carefully. See hydraulic hook-up section and
make sure the hoses do not contact any hot manifolds or sharp edges on tractor. After
assembly, raise the loader slowly and check to make sure that the hoses do not bind in all
positions.
The pressure of the relief and open center valves is set at the factory. Do not tamper with the
setting, serious injury to the operator or damage to the loader or tractor hydraulics may occur.
Warranty will be void if the loader is operated above recommended pressure.
9. When servicing any hydraulic components, care must be taken to prevent any foreign matter
from entering the system.
10. Do not neglect oil leaks. Leaks affect loader operation, are dangerous and can result in
personal injury or damage to the hydraulic system.
11. Never leave the cylinder shafts exposed when loader is not in use.
12. Worn or damaged components should be replaced as soon as possible with only the
manufacturer’s recommended component or equivalent.
CAUTION