Blomberg TAF 7230 A Clothes Dryer User Manual


 
17 - EN
Filter drawer (for products
equipped with a heat pump)
Lint and fibre that could not be caught
by the cover filter are blocked in the filter
drawerbehindthekickplate.“Condenser
cleaning” warning light will light up
periodically after a maximum 5 drying
cycles as a reminder.
In order to get the best performance from
your machine, clean the cover filter and the
filter drawer after each drying cycle. There
is a two-phase filter in the drawer. The first
phase is the cover filter and the second
phase is the filter sponge in the filter drawer.
To clean the filter drawer;
1 Pulloutthefilterdrawer.
2 Clean lint, fibre, and cotton raveling by
hand or with a soft piece of cloth.
3 Openthefilterdrawerbypressingthe
red button.
4 Take out the filter drawer sponge.
5 If the sponge is covered with lint
and fibers, it must be cleaned. Wash
the sponge by hand to clean it and
squeeze to drain excessive water.
After washing the sponge, any remaining
Cover filter
Lint and fibres released from the laundry
to the air during the drying cycle are
collected in the "Cover Filter". Such
fibre and lint are generally formed during
wearing and washing.
C Always clean the filter after each
Drying process.
For Filter cleaning;
1 Take out the cover
2 Lift the Cover filter up to pull out.
3 Clean lint, fibre, and cotton raveling by
hand or with a soft piece of cloth.
4 Placethefilterbackintoitsplace.
For the condenser (products
equipped with a condenser);
Hot and humid air in the condenser is
cooled with the cold air from the room. Thus,
the humid air circulating in your machine is
condensed and then pumped into the
tank.
C Clean the condenser after every 20
drying cycles or once a month.
To clean the condenser;
1 If a drying process has been carried
out, open the door of the machine and
wait until it cools down.
2 Unlock the 3 condenser locks after
opening the kick plate.
3 Pulloutthecondenser.
4 Clean the condenser with pressurized
water and wait until the water drains.
5 Replace the condenser with the side
labeled "Top" facing upwards. Lock
the 3 condenser locks.
6 Close the kick plate cover.
6 Maintenance and cleaning