Refer to the nearest Authorised Service
Agent for installation of your product.
C Preparation of location and electrical
installation for the product is under
customer’s responsibility.
B Installation and electrical connections
must be carried out by a qualified
personnel.
A Prior to installation, visually check if
the product has any defects on it. If
so, do not have it installed. Damaged
products will cause risks for your
safety.
Appropriate installation
location
Install the product in an environment
which has no risk of freezing and is in a
stable and level position.
Operate your product in a well
ventilated, dust-free environment.
Do not block the air ducts in front of
and under the product with materials
such as long pile rugs and cupboard
plinths.
Do not place your product on a long
pile rug or on similar surfaces.
Do not install the product behind a
door with a lock, sliding door or a
hinged door which can strike the
product.
Once the product is installed, it should
stay at the same place where its
connections have been made. When
installing the product, make sure
that the rear wall of it does not touch
anywhere (tap, socket, etc.) and also
pay attention to install the product at a
place where it will stay permanently.
BDo not place the product on top of the
power cable.
• Keep at least 1.5 cm distance to walls
of other furniture.
Under Counter Installation
• Leave at least 3 cm of space between
the side and rear walls of the machine
and the walls of the counter/cupboard
when installing your machine under a
counter or in a cupboard. Never use
the tumble dryer without top plate.
Ventilation hose and
connection (for products
equipped with an outlet vent)
Ventilation hose assures exhausting of the
air from inside the machine.
Vented dryer has 1 air outlet.
Stainless sheet metal or aluminum pipes
can be used instead of the hose. The
diameter of the pipe to be used should
be minimum 10 cm.
Maximum hose and pipe lengths are
given in the table below.
Hose Pipe
Maximum length 4 m 5 m
1 elbow 45° -1.0 m -0.3 m
1 elbow 90° -1.8 m -0.6 m
1 elbow 90° short -2.7 m
1 wall passage -2.0 m -2.0 m
C Each elbow and other passages
should be subtracted from the above
maximum length.
To connect a ventilation hose;
1. Connect the air outlet hose to the
hose spacer piece by turning it anti-
clockwise.
2. Make the hose passages as shown
below.
C Exhaust of humid air from the dryer
into the room is inconvenient. It may
damage the walls and furniture in the
room.
C The ventilation hose can be routed
outdoors via a window or it can be
connected to an air outlet in the wall
(see diagram below).
C Air outlet hose must be extended
directly to the outdoors. There must
be a small number of elbows as not to
hinder air ventilation.
C To prevent water accumulation in the
hose, make sure that it is not folded on
the oor.