Make sure that you have an earthed
power outlet socket rated at 13 amps
(minimum).
Attention!
If you use your dryer as built-in,
the socket must be reachable after
installation, or a separate switch (which
can disconnect the two poles) must
be used in the installation. Check for
suitability.
For a permanent connection, a master
switch with at least 3mm contact
clearance and minumum 13 A rating
must be used.
Electrical requirements
Before you insert the plug into the wall
socket make sure that the voltage and
the frequency shown in the rating label
corresponds to your electricity supply.
We recommend that this appliance be
connected to the mains supply via a
suitable switched and fused socket in a
readily accessible position.
Should the mains lead of the appliance
become damaged or need replacing at
any time, it must be replaced by a special
purpose made mains lead which can only
be obtained from a Authorised Service
Agent.
A Warning
This appliance must be earthed
If the fitted moulded plug is not suitable
for your socket, then the plug should be
cut off and an appropriate plug fitted.
The moulded plug on this appliance
incorporates a 13A fuse. Should the fuse
need to be replaced an ASTA approved
BS1362 fuse of the same rating must
be used. Do not forget to refit the fuse
cover. In the event of losing the fuse
cover, the plug must not be used until a
replacement fuse cover has been fitted.
Colour of the replacement fuse cover
must be the same colour as that visible
on the pin face of the plug. Fuse covers
are available from any good electrical
store.
In order to avoid hazards, damaged
supply cord should be replaced by the
manufacturer, its service agent or similarly
qualified people.
Built-under installation
This appliance can be installed under a
worktop.
A Only authorised specialists are
permitted to car ry out a built-under
installation. Risk of electric shock!
A Important
Fitting a different plug
As the colours of the wires in the
mains lead of this appliance may not
correspond with the coloured markings
identifying the terminals on your plug,
proceed as follows:
1 Connect the green - yellow or green
(earth) wire to the terminal in the plug
marked ‘E’ or with the symbol or
coloured green and yellow or green.
2 Connect the blue (neutral) wire to
the terminal in the plug marked ‘N’ or
coloured black.
3 Connect the brown (live) wire to
the terminal in the plug marked ‘L’ or
coloured red.
With the alternative plugs a 13A fuse
must be fitted either in the plug or
adaptor or in the main fuse box. If in
doubt contact a qualified electrician.
4 Electrical Connection