American Dryer Corp. SL2020 Clothes Dryer User Manual


 
16 American Dryer Corp. 113401-18
Electric Models Only
All electrically heated dryers must be connected to the electric
service shown on the dryer’s data label. The connecting
wires must be properly sized to handle the rated current.
Electrical Service Specifications
Gas and Steam Models Only
7/10/08
ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET)
IMPORTANT:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify
exact voltage.
When fuses are used they must be dual element, time delay, current limiting,
class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying
either local and/or National Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others,
calculate/verify correct breaker size according to appliance amp draw rating
and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
kW PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz 50 Hz
SL2020
200 5.6 2 32.7 32.7 45
208 4.1 2 24.2 35
208 6.1 2 34.0 45
220 6.8 2 35.6 45
230 5.0 2 26.4 35
230 7.4 2 36.8 50
240 5.4 2 27.1 35
240 8.1 2 38.4 38.4 50
208 6.5 3 22.7 30
240 7.5 3 22.6 30
380 6.8 4 15.0 20
400 7.5 4 15.5 20
416 8.1 4 15.8 20
SL3131
200 12.5 2 68.4 67.7 90
208 7.9 2 43.8 60
208 13.5 2 70.7 90
230 8.3 2 41.3 60
230 12.4 2 59.1 80
240 9.0 2 42.7 60
240 13.5 2 61.5 80
208 13.5 3 43.3 60
220 11.3 3 35.3 50
230 12.4 3 36.5 50
240 13.5 3 37.7 50
380 11.3 4 22.8 22.6 40
400 12.4 4 23.1 40
416 13.5 4 23.7 40
7/10/08
ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET)
IMPORTANT:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz 50 Hz
SL2020 Gas
120 2 8.9 15
200 2 7.7 7.8 15
208 2 7.6 15
220 2 7.4 15
230 2 7.3 15
240 2 7.2 7.0 15
SL2929 Gas
120 2 8.9 15
SL3131 Gas
120 2 10.3 15
200 2 8.7 8.8 15
208 2 8.4 15
220 2 8.1 8.1 15
230 2 7.4 15
240 2 7.7 7.0 15
SL3131 Steam
120 2 9.3 15
208 2 6.2 6.0 15
220 2 5.6 5.5 15
230 2 5.4 15
240 2 5.1 15