B. FREE MODE
1. When the controller is in the ready state and no cycle is in progress, the liquid crystal display (L.C.D.)
screen will display “SELECT TEMP TO START”.
2. Select temperature by pressing “HI” , “MED” , or “LO” . The cycle will start and the controller will
display the Dry Cycle selected and the remaining time.
3. The dryer will continue through the drying and cooling cycles, until the drying time has expired.
4. Upon completion of the drying and cooling cycles, the buzzer will sound, and the dryer will go into
Wrinkle Guard mode for 99 minutes or until the door has been opened.
5. HOT KEYS – In free mode, the HOT KEYS are always enabled. The HOT KEYS are as follows:
Pressing and holding the “HI” key will show the remaining dry time available.
Pressing and holding the “MED” key will show the temperature readings of the exhaust probe. The
exhaust probe temperature reading is displayed on the left. If the dryer is an axial model, the temperature
reading of the axial temperature transducer will also be displayed, this will be the middle temperature
reading.
Pressing and holding the “LO” key will show the RPMs of the basket (tumbler).
The “PAUSE” key will pause the dryer. If the dryer is paused, pressing the “HI” , “MED” , or “LO”
key will restart the dryer into the appropriate drying cycle. Once the dry cycle has started again, the
HOT KEYS will be enabled again.
C. PAUSE MODE
If the “PAUSE” key is pressed and the door is not opened, the dryer will restart in 20-seconds. If the
“PAUSE key is pressed and the dryer door is opened and left open, the dryer will wait for the pause time
defined in PL01 to expire. Once the pause time expires, the controller will begin to count down the dry time. If
the dryer door is opened without first pressing the “PAUSE” key the controller will continue to count down the
dry time.
D. RPM
The Phase 7 dual microprocessor controller (computer) also displays the basket (tumbler) RPM by pressing and
holding the “LO” key while the basket (tumbler) is rotating (the basket [tumbler] must be rotating for
approximately 30-seconds before getting a true RPM reading). In coin mode, the program switch must be in
the “UP” position.