American Dryer Corp. MLG31PCB Clothes Dryer User Manual


 
26 Maytag 113203-3
4) The dryer will continue through the drying and cooling cycles until the time vended has expired.
NOTE: The dryer can be stopped at any time by opening the main loading door or pressing the pause
key. To restart the dryer, press appropriate temperature selection key.
5) Upon completion of the drying and cooling cycles, the buzzer will sound, and the dryer will go into
the Anti-Wrinkle mode for 99 minutes, or until the main door is opened.
IMPORTANT: For complete operation details for the computer system refer to the user’s manual
included with the dryer.
b. FREE Dry Mode
1) The liquid crystal display (L.C.D.) screen reads “Select Temperature.”
2) Select temperature by pressing “HIGH,” “MEDIUM,” or “LOW.” The cycle/dryer will start and
the display will read cycle time.
3) The dryer will continue through the drying and cooling cycles until the drying time and cooling time
has expired.
NOTE: The dryer can be stopped at any time by opening the main loading door or pressing the pause
key. To restart the dryer, press appropriate temperature selection key.
4) Upon completion of the drying and cooling cycles, the buzzer will sound, and the dryer will go into
the Anti-Wrinkle mode for 99 minutes, or until the main door is opened.
IMPORTANT: For complete operation details for the computer system refer to the user’s manual
included with the dryer.
3. Heat Circuit Operational Test
Gas Models
When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition
attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to
be purged from the lines.
The dryer is equipped with a Direct Spark Ignition (DSI) system, which has internal diagnostics. If ignition
is not established after three (3) attempts, the heat circuit DSI module will lock out until it is manually reset.
To reset the DSI system, open and close the main door and restart the dryer (press desired temperature
selection).
NOTE: During the purging period, check to be sure that ALL gas shutoff valves are open.
Once ignition is established, a gas pressure test should be taken at the gas valve pressure tap of each
dryer to ensure that the water column (W.C.) pressure is correct and consistent.