113344-9 www.amdry.com 17
* Contact factory for 3-wire system. 8/4/08
IMPORTANT: The dryer must be connected to the electric supply shown on the data label. In the
case of 208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
3. Electrical Connections
NOTE: A wire diagram is located in the front electrical control box for connection data.
NOTE: A CIRCUIT SERVICING EACH DRYER MUST BE PROVIDED.
Gas and Steam
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value,
by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.
For others, calculate/verify correct breaker size according to appliance
amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz 50 Hz
208 3 14.4 20
240 3 14.0 15.9 20
380-400 4* 8.4 15
416 4* 8.7 15
440 4* 8.6 15
460/480 3 7.5 15
2. Electrical Service Specifications