a. Gas Connections:
Inlet connection 1 inch N.P.T.
Inlet supply size 1 inch N.P.T. (minimum)
Btu/hr input (per dryer) 270,000
1.Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must be
consistent between a minimum of 6.0 inches and a maximum of 12 inches water column pressure.
2. Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so that the
gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure
tap must be a consistent 11 inches water column. There is no regulator or regulation provided in an L.P.
dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must
be added to each dryer.
* D.M.S. (Drill Material Size) equivalents are as follows:
Natural Gas @23 = .154"
Liquid Propane Gas @41 = .096"
Type of Gas
L.P.
Conversion
Kit Part
Number
Natural Liquid Propane
Model
Number
BTU Per
Hour
Rating
Qty. D.M.S.*
Part
Number
Qty. D.M.S.*
Part
Number
MLG-82 270,000 4 #23 140856 4 #41 140811 882119