American Dryer Corp. ML-75V Clothes Dryer User Manual


 
50
OPTIONAL MANUAL BYPASS
Provisions are made in the dryer’s F.S.S. for the installation of an optional manual bypass. Depending on the
model dryer, the connections for the manual bypass are made at the “T” or “four way” fitting located in the outlet
supply side of the water solenoid valve. The use and connections of this manual bypass are at the option or
discretion of the owner.
The water connection for the manual bypass is made to the “T” or “four way” fitting which has a 3/8” F.P.T. and
a coupling must be used to provide the minimum 1/2” supply (feed) line.
If the rear area of the dryer, or the water supply is located in an area where it will be exposed to cold/freezing
temperatures, provisions must be made to protect these water lines from freezing.
WARNING: If the water in the supply line or water solenoid valve freezes, the F.S.S. will be
INOPERATIVE!!
The manual ball cock shutoff valve must be located outside of the dryer at a distance from the dryer where it
is easily accessible.
3. Electrical Requirements
No independent external power source or supply connection is necessary. The 24 volt power to operate the
F.S.S. is accomplished internally in the dryer (from the dryer controls).
WARNING: Electrical power must be provided to the dryer at ALL times. If the main electrical
power supply to the dryer is disconnected, the F.S.S. is INOPERATIVE!!