ALL electrically heated dryers must be connected to the electric service shown on the dryer’s data
label. The connecting wires must be properly sized to handle the rated current.
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker
size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz 50 Hz
30 kW
208 3 91 * 125 125
230 3 83 * 125 125
240 3 79 * 100 100
380 3 48 * 60 60
380 4** 54 * 70 70
400 4** 51 * 70 70
416 4** 50 * 70 70
460 3 40 * 50 50
480 3 39 * 50 50
575 3 33 * 50 50
36 kW
208 3 108 * 150 150
230 3 98 * 125 125
240 3 94 * 125 125
380 3 58 * 80 80
380 4** 63 * 80 80
400 4** 60 * 80 80
416 4** 58 * 80 80
460 3 48 * 60 60
480 3 46 * 60 60
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify
correct breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz 50 Hz
120 2 13.0 * 20 20
208 2 7.6 * 15 15
220 2 7.3 8.6 * 15 15
230 2 8.0 * 15 15
240 2 7.0 * 15 15
208 3 4.7 * 15 15
230 3 4.7 * 15 15
240 3 4.9 * 15 15
380 3 2.9 * 15 15
380 4** 3.1 * 15 15
400 4** 3.2 * 15 15
416 4** 3.1 * 15 15
460/480 3 2.8 * 15 15