American Dryer Corp. ML-175 Clothes Dryer User Manual


 
37
K. COMPRESSED AIR REQUIREMENTS
The model ML-175 dryer requires an external supply of compressed air (2.5 cfm @ 80 PSI for gas models and
6 cfm @ 80 PSI for steam models). For Steam Models, compressed air is necessary for the air operated steam
damper. On both the Steam Model as well as the Gas Models, compressed air is necessary/required for blower
air jet operation...to clean lint from the impellor/fan (squirrel cage).
1. Air Requirements
a. Microprocessor (computer) dryers...
COMPRESSED AIR SUPPLY AIR PRESSURE
Normal 80 PSI
Minimum Supply 70 PSI
Maximum Supply 90 PSI
2. Air Regulation
a. No air regulation or air filtration is provided with the dryer. External regulation/filtration of 80 PSI
must be provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed
air line just before the dryer connection. This is necessary to insure that correct and clean air pressure is
achieved.
3. Air Connection
a. Air connection to this system is a 1/8” F.P.T. (female pipe thread) as per the illustration below.