American Dryer Corp. ML-175 Clothes Dryer User Manual


 
27
3. Piping/Connections
ALL components/materials must conform to National Gas Code Specifications. It is important that gas
pressure regulators meet applicable pressure requirements and that gas meters be rated for the total amount
of ALL the appliance BTU's being supplied.
The dryer is provided with a 1-1/2 inch N.P.T. inlet pipe connection extending out the back area of the burner
box. The minimum pipe size (supply line) to the dryer is 1-1/2 inch N.P.T. For ease servicing, the gas supply
line of each dryer must have its own shut-off valve.
The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas
meter or, in the case of L.P. (liquid propane) gas, the supply tank, other gas-operated appliances on the same
line, etc. Specific information regarding supply line size should be determined by the gas supplier.
NOTE: Undersized gas supply piping can create a low or inconsistent pressure which will result in
erratic operation of the burner ignition system.
Consistent gas pressure is essential at ALL gas connections. It is recommended that a 1-1/2 inch pipe gas
loop be installed in the supply line serving a bank of dryers. An in-line pressure regulator must be installed
in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches of water column (W.C.)
pressure.
NOTE: A consistent water column (W.C.) test pressure of 3.5 inches for natural gas and 10.5 inches
for L.P. (liquid propane) dryers is required at the gas valve pressure tap of each dryer for
proper and safe operation.
A 1/8" N.P.T. plugged tap, accessible for a test gauge connection, must be installed in the main gas supply
line immediately upstream of each dryer.
IMPORTANT: Pipe joint compounds that resist the action of natural gas and L.P. gas must be used.
IMPORTANT: Test ALL connections for leaks by brushing on a soapy water solution (liquid
detergent works well).
WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!
ALL components/materials must conform to National Gas Code Specifications ANSI Z223.1-LATEST
EDITION.
It is important that gas pressure regulators meet applicable pressure requirements and that gas meters be
rated for the total amount of ALL the appliance BTU's being supplied.