American Dryer Corp. EURO-14 Clothes Dryer User Manual


 
6
SECTION II
SPECIFICATIONS
A. SPECIFICATIONS
* EURO-14 reversing dryer is available with 3-phase (3ø) motors standard (1/2 HP [0.373 kw] motors).
** Size of piping to dryer varies with installation conditions. Contact factory for assistance.
*** Contact factory for information not listed, 3-phase (3ø) figures shown are for 3-wire service.
**** Specify air-operated or electromechanical steam damper system. Air-operated steam damper system must be provided with clean,
dry, and regulated (80 PSI +/- 10 PSI [5.51 bars +/- 0.68 bars]) air supply.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
GasElectricSteam****
MAXIMUM CAPACITY (DRY WEIGHT) 30 lbs
13.6 kg
BASKET (TUMBLER) DIAMETER 32-3/4” 83.2 cm
BASKET (TUMBLER) DEPTH 25-5/8” 65.1 cm
BASKET (TUMBLER) MOTOR 1/2 HP* 0.373 kw
DOOR OPENING (DIAMETER) 21-1/2”
54.61 cm
BASKET (TUMBLER) VOLUME 12.5 cu. ft.
0.354 cu.m.
DRYERS PER 20’/40’ CONTAINER 12/26
DRYERS PER 48’/53’ TRUCK 30/32
VOLTAGE AVAILABLE 120-460v 1ø - 3ø 3, 4w 50/60 Hz
APPROX. WEIGHT (UNCRATED) 534 lbs 242 kg
APPROX. WEIGHT (CRATED) 571 lbs
259 kg
HEAT INPUT 95,000 btuh 23,940 kcal/hr
AIRFLOW 750 cfm 21 cmm
INLET PIPE CONNECTION 1/2” F.P.T.**
OVEN SIZE
KW
BTUH
(60 HZ)
KCAL/HR
(50 Hz)
15 51,195 12,900
20 68,260 17,200
24 81,910 20,640
30 102,390
25,800
APPLIED VOLTAGE/PHASE/APPROX. AMP DRAW***
KW
208/1ø 240/1ø 208/3ø 240/3ø 380/3ø 416/3ø 460/3ø
50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
15 --- --- 47 41 --- --- ---
20 102 89 --- --- 36 --- ---
24 --- --- 72 63 --- 39 34
30 --- --- 88 77 --- 47 41
VOLTAGE AVAILABLE 120-460v 1ø - 3ø 3, 4w 50/60 Hz
APPROX. WEIGHT (UNCRATED) 593 lbs 269 kg
APPROX. WEIGHT (CRATED) 631 lbs 286 kg
AIRFLOW 750 cfm
21 cmm
COMPRESSED AIR VOLUME 0.5 cfh 0.014 cmh
AIR CONNECTION 1/8” F.P.T.
STEAM CONSUMPTION BOILER HP NORMAL LOAD
LOW 90.1 lbs/hr 40.9 kg/hr 2.6
HIGH 104 lbs/hr 47.2 kg/hr 3.0
OPERATING STEAM PRESSURE STEAM SUPPLY STEAM RETURN
LOW 15 PSI 1.03 bars 1” 1”
HIGH 125 PSI 8.6 bars 1” 1”
Shaded areas are stated in metric equivalents