American Dryer Corp. AD-120ES III Clothes Dryer User Manual


 
62
SECTION XI
BURNER AND BASKET (TUMBLER)/LINT CHAMBER
MANUAL RESET HI-LIMIT INSTRUCTIONS
I M P O R T A N T
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR TIMER OR PHASE 5 WITHOUT HEAT FAULT
(GAS MODELS ONLY)
This dryer was manufactured with a burner and basket (tumbler)/lint chamber burner manual reset hi-limit
thermostat. If either burner manual reset hi-limit thermostat is open prior to the start of the drying cycle, or
during the cycle, the dryer will not recognize the open state of the burner hi-limit thermostat and will start or
continue through the drying cycle with no heat. The applicable manual reset hi-limit thermostat must be reset
manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner oven
operation.
The location of the burner manual reset hi-limit switch is on the right side of the burner box.
IMPORTANT
This dryer is equipped with a burner hi-
limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N:114093