Alliance Laundry Systems Washer/Dryer Washer/Dryer User Manual


 
Installation
13
801504
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Step 5: (Electric Dryer Only) Connect
Electrical Plug
For further assistance, refer to section on Electrical
Requirements.
IMPORTANT: Use only a new U.L. listed No. 10
(copper wire only) three conductor power supply
cord kit rated 240 Volts (minimum) 30 Amperes
and labeled as suitable for use in a clothes dryer.
Figure 12
NOTE: For more detailed information on
connecting three-wire or four-wire plugs, refer to
section on Electric Dryer Electrical Requirements.
NOTE: Four-wire cord is required for mobile
homes or where codes do not permit grounding
through neutral.
Figure 13
D275I
D006I
1 Typical Receptacle
2 Power Cord (Not supplied with dryer)
3 Strain Relief Nut
4 Strain Relief
1
2
3
4
THREE-WIRE
1
2
3
4
FOUR-WIRE
D679I
D680I
NOTE: Dryer is shown with access cover removed for
illustration purposes only. NEVER operate the dryer
with access cover removed.
1 Ground Wire
2 Ground to Neutral Wire
3 Neutral Terminal
4 L2 Terminal
5 Center Wire (Neutral)
6 Strain Relief (Not supplied with dryer)
7 Ground Screw
8 L1 Terminal
9 Black Wire
10 White Wire (Neutral)
11 Red Wire
D679I
1
8
7
6
5
4
3
2
THREE-WIRE CONNECTION
D680I
1
8
7
6
10
4
3
1
11
9
FOUR-WIRE CONNECTION