Alliance Laundry Systems Washer Washer User Manual


 
Programming
F232133
16
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Setting the Parameters
1. Locate the two buttons above and to the left of
the microprocessor. Refer to Figure 17.
2. Press and release both buttons at the same time to
enter PROGRAM Mode. The digital display will
show “AtS”.
3. Press either the left or right button until the
desired parameter is displayed. Refer to Table 4
to see parameters and their meanings.
4. Press and release both buttons at the same time
to display the setting for the selected parameter.
Press the left or right button to change the
parameter setting. When setting numerical
values, the right button increases the displayed
value and the left button decreases the
displayed value. Pressing and holding one of the
buttons causes the displayed value to change
more rapidly.
5. Once the desired parameter value is displayed,
press and release both buttons at the same time to
accept the new value.
6. To change another parameter setting, return to
step 3.
7. To return to RUN Mode, press the right or left
button until the digital display shows “End”.
Press and release both buttons at the same time.
The display will then either show a vend price or
alternately flash “PAY” and a vend price.
Display
Programming Parameters
AtS – Amount to Start Amount value required to start a single wash. Single coin: value must be evenly
divisible by the APC setting. Dual coin: value should be evenly divisible by both
Cn1 and Cn2 values.
APC – Amount Per Coin Value of each coin inserted into the coin meter.
Cn1 – Coin 1
(Dual coin only)
Value of each coin inserted to the right slot of the coin meter (as viewed from the
front).
Cn2 – Coin 2
(Dual coin only)
Value of each coin inserted to the left slot of the coin meter (as viewed from the front).
ACC – Accumulate How the display will show the start amount. Set to “UP” to display value of coins
inserted in the meter; set to “Dn” to display the difference between the value of the
inserted coins and the AtS.
FLS – Flash Set to “YES” to have the display flash; set to “no” to have the display not flash.
Crd – Credit
(Dual coin only)
Determines whether or not overpayment by a customer is credited to the next wash. Set
to “YES” for the amount of overpayment to be credited to the next wash. The display
will show either a reduced vend price or the amount of overpayment, depending on the
setting of the ACC parameter; set to “no” for no credit given to overpayment.
Lot – Lock-Out Time Determines the amount of time in seconds the coin counter board will pause when a
bad coin is inserted. When a bad coin is inserted, the display will read “Err” for this
amount of time.
Rot – Relay-On Time
Ctr – Counter Read-only parameter keeps track of the number of cycles the washer-extractor has
performed.
dPt – Decimal Point Determines the position of the decimal point in the digital display. Set to “000” for no
decimal point; set to “001” for the decimal point to display on the right side of the
center digit; set to “002” to display on the left side of the center digit.
Table 4