Alliance Laundry Systems HC18 Washer User Manual


 
47
Installation
F232062
Cabinet Hardmount
Electrical Specifications
18-Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2-Speed Models
B 110-120 60 1 2 15 20 12 4.00 N/A
C380-41550344 15142.501415142.50
D220-24050335 15142.502425106.00
E 220-240 50 1 2 10 20 12 4.00 42 45 6 16.0
F440-48060334 15142.501620124.00
O208-24060335 15142.502425106.00
U
380 50344 15142.501415142.50
240 50335 15142.502425106.00
Y 208-240 60 1 2 10 20 12 4.00 N/A
3-Speed Models
A208-24060347 15142.502430106.00
C380-41550345 15142.501520124.00
D220-24050337 15142.502430106.00
F440-48060335 15142.501520124.00
O208-24060337 15142.502430106.00
Variable-Speed Models
O 208-240 60 3 3 3.84 15 14 2.50 N/A
Y 208-240 60 1 2 3.84 15 14 2.50 N/A
Note:
Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.