Installation
800536
16
Electrical Requirements
(120 Volt, 60 Hertz with 3-Prong Grounding Plug)
NOTE: The wiring diagram is located in the
control cabinet.
Figure 12
The washer is designed to be operated on a separate
branch, polarized, three-wire, effectively grounded,
120 Volt, 60 Hertz, AC (alternating current) circuit
protected by a 15 ampere fuse, equivalent fusetron or
circuit breaker.
The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 110/120 Volts
AC (alternating current) 15 Amps. Refer to Figure 13
to determine correct polarity of the wall receptacle.
DO NOT OPERATE OTHER APPLIANCES ON
THE SAME CIRCUIT. DO NOT OVERLOAD
CIRCUITS!
Grounding Instructions
The washer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. The washer is equipped
with a cord having an equipment-grounding conductor
and a 3-prong grounding plug. The plug must be
plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
D009I
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA No. 70, and such local
regulations as might apply. It is the
customers responsibility to have the
wiring and fuses checked by a qualified
electrician to make sure the laundry room
has adequate electrical power to operate
the washer.
W227
WARNING
DO NOT OVERLOAD
CIRCUITS
DO NOT USE
ADAPTER
DO NOT USE AN
EXTENSION CORD
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the washer to the
electric power source.
W082
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or serviceman if you are in
doubt as to whether the washer is
properly grounded.
W216
WARNING