Programming
11
F232139
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Armstrong S-Series Microcomputers
NOTE: This section deals with machines that have
the Armstrong S-series microcomputer only. When
power is supplied to the machine, an Armstrong
microcomputer will read “S 14”.
Programming Mode
In the program mode, where the operator creates and
changes cycle programs, some display messages have
been changed. Refer to Table 3.
Table 4
*NOTE: Because the COLD water valve might
remain energized for some time, it is necessary to
ensure that the machine has a suitable overflow
connection.
Automatic Cool-Down
NOTE: Can be disabled.
The automatic cool-down feature prevents the drain
from opening until the temperature of the water in the
sump falls below 140
°
F (60
°
C).
This feature becomes active during a drain step, if the
step is programmed for “drAI” when the temperature
is above the threshold temperature. During the
cool-down, the COLD fill valve is energized, the drain
remains closed and the machine continues to agitate as
it did prior to the cool-down. When the temperature
falls below 140
°
F (60
°
C), the COLD fill valve turns
off and the drain step proceeds as normal.
Enabling/Disabling Cool-Down
NOTE: Factory default is disabled.
To enable or disable the cool-down feature, first enter
Program Mode, refer to page 7, then proceed as
follows:
1. After entering Program Mode display shows
temperature. Press Stop (*) key.
2. Display shows “
°
CEL”. Press Start (#) key.
3. Display shows “HEAt”. Press Start (#) key.
4. Display shows “CooL” if cool-down is enabled
or “noCL” if disabled. To change this, press Up
or Down (arrow) key.
5. Press Start (#) key to save and return to Program
Mode.
Previous software display
New software
display
PrE
(Prewash step)
FIL1
PrEU
(Prewash, no “sluice” selected)
FILL
SLUC
(Step contained a “sluice”)
ovEr
(Overflow fill)*
UASH
(Wash step)
FIL2
FIL1 FIL3
FIL2 FIL4
FIL3 FIL5
drin
(“dilution rinse” no sluice)
FILL
FIL4 FIL6
FIL5 FIL7
FIL6 FIL8