Electrical Specifications
Electrical Specifications
20 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2 Speed Models
B 120 60 1 2 16 20 12 4.0 N/A
C 380 – 415 50 3 4 4 15 14 2.5 14 15 14 2.5
F 440 – 480 60 3 3 4 15 14 2.5 N/A
J 200 50 3 3 5 15 14 2.5 N/A
O 208 – 240 60 3 3 5 15 14 2.5 23 30 10 6.0
Y 208 – 240 60 1 2 8 15 14 2.5 N/A
Variable-Speed Models
Q 200 – 240 50/60 3 3 4 15 14 2.5 21 30 10 6.0
R 380 – 480 50/60 3 3 4 15 14 2.5 N/A
X 200 – 240 50/60 1/3 2/3 6/4 15 14 2.5 N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 6
Electrical Specifications
30 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2 Speed Models
C 380 – 415 50 3 4 4 15 14 2.5 15 20 12 4.0
F 440 – 480 60 3 3 4 15 14 2.5 N/A
J 200 50 3 3 7 15 14 2.5 N/A
O 208 – 240 60 3 3 7 15 14 2.5 25 30 10 6.0
Y 208 – 240 60 1 2 10 20 12 4.0 N/A
Variable-Speed Models
Q 200 – 240 50/60 3 3 5 15 14 2.5 22 30 10 6.0
R 380 – 480 50/60 3 3 4 15 14 2.5 N/A
X 200 – 240 50/60 1/3 2/3 7/5 15 14 2.5 N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.