Alliance Laundry Systems CHM166C Washer/Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
21
F232145 (EN)
Electrical Specifications
35 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2 Speed Models
C 380 – 415 50 3 4 5 15 14 2.5 26 30 10 6
D 220 – 240 50 3 3 7 20 12 4 43 50 6 16
F 440 – 480 60 3 3 5 15 14 2.5 26 30 10 6
O 200 – 240 60 3 3 7 20 12 4 43 50 6 16
Y 208 – 240 60 1 2 12 25 10 6 N/A
Variable-Speed Models
N 440 – 480 50/60 3 3 2.3 15 14 2.5 27.3 30 10 6
P 380 – 415 50/60 3 3 2.3 15 14 2.5 24 25 10 6
Q 208 – 240 50/60 3 3 5.9 15 14 2.5 43.4 45 6 16
T 200 – 240 50/60 1 2 5.9 15 14 2.5 N/A
X 200 – 240 50/60 1 or 3 2 or 3 5.9/5.9 15 14 2x2.5
3x2.5
N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 9
Electrical Specifications
40 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2 Speed Models
C 380 – 415 50 3 4 5 15 14 2.5 26 30 10 6
D 220 – 240 50 3 3 7 20 12 4 45 50 6 16
F 440 – 480 60 3 3 5 15 14 2.5 29 30 10 6
H 380 60 3 3 3 15 14 2.5 25 30 10 6
J 200 50 3 3 7 20 12 4 38 40 6 16
O 208 – 240 60 3 3 7 20 12 4 45 50 6 16
Y 208 – 240 60 1 2 13.5 30 10 6 N/A
Variable-Speed Models
N 440 – 480 50/60 3 3 6 15 14 2.5 30 30 10 6
P 380 – 415 50/60 3 3 6 15 14 2.5 29 30 10 6
Q 200 – 240 50/60 3 3 5 15 14 2.5 48 60 6 16
X 200 – 240 50/60 1 or 3 2 or 3 11/11 15 14 2.5 N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 10