Alliance Laundry Systems CHM166C Washer/Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
F232145 (EN)
20
Electrical Specifications
Electrical Specifications
18 and 20 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2 Speed Models
B 110 – 120 60 1 2 15 20 12 4 N/A
C 380 – 415 50 3 4 4 15 14 2.5 14 15 14 2.5
D 220 – 240 50 3 3 5 15 14 2.5 24 25 10 6
E220 2405012102012 4 4245 6 16
F 440 – 480 60 3 3 4 15 14 2.5 16 20 12 4
H 380 60 3 3 4 15 14 2.5 13 15 14 2.5
J 200 50 3 3 5 15 14 2.5 24 25 10 6
O 208 – 240 60 3 3 5 15 14 2.5 24 25 10 6
Y208 2406012102012 4 4245 6 16
Variable-Speed Models
Q 200 – 240 50/60 3 3.8 3.8 15 14 2.5 N/A N/A N/A N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 7
Electrical Specifications
25, 27 and 30 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2 Speed Models
C 380 – 415 50 3 4 4 15 14 2.5 15 20 12 4
D 220 – 240 50 3 3 6 15 14 2.5 24 25 10 6
E220 2405012102012 4 4245 6 16
F 440 – 480 60 3 3 4 15 14 2.5 16 20 12 4
H 380 60 3 3 4 15 14 2.5 14 15 14 2.5
J 200 50 3 3 6 15 14 2.5 20 25 10 6
O 208 – 240 60 3 3 7 15 14 2.5 25 30 10 6
Y 208 – 240 60 1 2 10 20 12 4 43
45616
Variable-Speed Models
Q 200 – 240 50/60 3 3 4.8 15 14 2.5 N/A N/A N/A N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 8