Alliance Laundry Systems UM202 Washer/Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
11
F232212
Installation
Dimensional Clearances
Refer to Figure 5 for recommended dimensional
clearances.
Figure 5
Machine Foundation
The machine may be placed on any level floor as long
as floor will hold the weight of the machine.
Position the machine and level with shims or grout
under the corners.
Refer to Table 3 for static loads on the floor.
Machine Anchoring
Bolting to floor is optional. To bolt down the machine,
use 3/8 inch bolt holes located on the frame at the
bottom of each corner. One quarter inch machine
anchors should be used.
CAR10N
CAR10N
6 in.
(152 mm)
1/2 in.
(13 mm)
6 in.
(152 mm)
Floor Load Data
Specification
Static floor load 840 lbs.
(3.7 kN)
Static pressure 68 lbs-ft
2
(3.3 kN-m
2
)
Table 3