Alliance Laundry Systems 802715 Washer Accessories User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 802715
10
NOTE: The dryer and its appliance main gas valve
must be disconnected from the gas supply piping
system during any pressure testing of that system
at test pressures in excess of 1/2 psi (3.45 kPa).
Refer to Step 12 (Check Heat Source).
L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft
3
(93.1 MJ/m
3
) service must be supplied at 10 ± 1.5 inch
water column pressure.
For proper operation at altitudes above 3000 feet
(915 m) the L.P. gas valve spud orifice size must be
reduced to ensure complete combustion. Refer to
Table 2.
NOTE: DO NOT connect the dryer to L.P. Gas
Service without converting the gas valve. Install
L.P. Gas Conversion Kit 649P3, available at extra
cost.
Step 5: (Electric Dryer Only) Connect
Electrical Plug
Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz,
3 or 4 wire electrical suppy. Refer to serial plate for
specific electrical requirements.
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
Grounding Information
This dryer must be connected to a grounded
metal, permanent wiring system; or an
equipment-grounding conductor must be run
with the circuit conductors and connected to the
equipment-grounding terminal or lead on the
dryer.
The dryer has its own terminal block that must be
connected to a separate branch, 60 Hertz, single
phase circuit, AC (alternating current) circuit,
fused at 30 Amperes (the circuit must be fused
on both sides of the line). Electrical service for
the dryer should be of maximum rated voltage
listed on the nameplate. Do not connect dryer
to 110, 115, or 120 volt circuit.
Heating elements are available for field
installation in dryers which are to be connected to
electrical service of different voltage than that
listed on nameplate, such as 208 Volt.
If branch circuit to dryer is 15 feet (4.57 m) or
less in length, No. 10 AWG wire (copper wire
only), or as required by local codes. If over
15 feet (4.57 m), use No. 8 AWG wire (copper
wire only), or as required by local codes. Allow
sufficient slack in wiring so dryer can be moved
from its normal location when necessary.
The power cord connection between wall
receptacle and dryer terminal block IS NOT
supplied with dryer. Type of power cord and
gauge of wire must conform to local codes.
L.P. Altitude Adjustments
Altitude Orifice Size
Part No.
feet m No. inches mm
3000 915 55 0.0520 1.32 58755
8000 2440 56 0.0465 1.18 503786
Tabl e 2
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local
regulations as might apply. It is the
customer’s responsibility to have the wiring
and fuses installed by a qualified electrician
to make sure adequate electrical power is
available to the dryer.
W521
WARNING