Alliance Laundry Systems 25 Clothes Dryer User Manual


 
Operating Instructions
70400201
16
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
DMP Coin Features
Coin Keypad Interface
- START button to start or resume a cycle.
- TEMP button to select HIGH, MEDIUM, or LOW
temperature.
- Two hidden buttons to increment or decrement the
programmable time and temperature options.
Power-Up
Upon applying power to the tumbler, the display will
show “PAy” and the DRYING and COOLING LEDs
will be off until coins are deposited to increase the
tumbler run time. When time is displayed, the default
(LOW) temperature setting LED will be on until a
different temperature setting is selected.
Power Failure
If a power loss occurs during operation, a cycle will
not resume until the START button is pressed. To
cancel the remaining cycle, press the internal CLEAR
button.
Coin Operation
The tumbler run time is determined by the pre-
programmed run time per coin and the number of
coins deposited into the tumbler. The maximum time
that can be accumulated and displayed is 99 minutes.
The drying time is the difference between the run time
and the cooling time. The cooling time is pre-
programmed to be 2 to 5 minutes. The drying
temperature can be selected from LOW, MEDIUM, or
HIGH temperature settings by pressing the TEMP
button.
Coin Programming
The Coin board programming mode can only be
entered when “PAy” is displayed. DIP switch #7 must
be in the OFF position.
Programming is enabled by setting DIP switch #8 to
the ON position.
The programming mode is entered by pressing and
holding the CLEAR button for three seconds.
The programming follows the following parameter
order:
1. Tumbler run time per coin (DRYING),
COOLING time, HIGH temperature setpoint,
MEDIUM temperature setpoint, LOW
temperature setpoint.
2. An LED will be on to indicate which parameter is
flashing on the display.
3. The hidden front panel increment and decrement
keys are used to change the value.
4. The CLEAR button is used to recall the default
value.
5. The START button is used to step to the next
parameter.
6. After the last parameter, “End” will be flashing.
7. Press the START button one last time to store the
settings and exit the program mode.
8. “PAy” will be displayed.
9. If it is determined that the data did not program
correctly, the error message “E2F” will flash for
4 seconds, and then the default coin parameters
will be used.
The tumbler run time per coin is programmable for 1
to 20 minutes with the default preset to 10 minutes.
The cooling run time is programmable from 2 to
5 minutes with the default preset to 2 minutes.
The three temperatures setpoints are programmable for
100ºF (38ºC) to 185º/195ºF (85º/90ºC) with the
following default settings:
- HIGH equal to 185ºF (85ºC)
- MEDIUM equal to 150ºF (66ºC)
- LOW equal to 135ºF (57ºC)
Stop
When in the Coin mode, the tumbler will stop if the
tumbler door is opened while the tumbler is running. If
the CLEAR button, located behind the board, is
pressed, the tumbler will stop, the tumbler time will be
zeroed and the display will show “PAy.”
Coin Count
The unit will count the number of coins deposited.
Setting DIP switch #7 to the ON position will display
the coin count since it was the last reset.
To reset the count, press the CLEAR button and “00”
will be displayed.
If the coin count is greater than “999,” the display will
flash “999.”
Setting DIP switch #7 to the OFF position will return
the display to “PAy.”