f. Troubleshooting Flowchart - Quick Reference...
Third Visual Check
MAIN BURNER LIGHTS BUT DOES NOT STAY ON
Is flame sensor cable
securely attached
to terminal 4?
NO YES
Does continuity exist
from control
to flame sensor?
NO YES
Is flame sensor corroded
or is ceramic cracked?
NO YES
Does continuity exist in
ground path from burner to
control?
NO YES
Check flame sensing
current during trial.
Is current greater than
0.3µ A DC*?
NO YES
Is flame sensor positioned
per manufacturer’s
specifications?
NO YES
Correct
Correct
Correct
Replace
Johnson Control
module
G760/761
Replace
Johnson Control
module
G760/761
Replace
sensor
cable.
Correct or
replace
sensor.