![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/6b/36b0fb4b-f3e0-423c-b967-f4ec2adc9b86/36b0fb4b-f3e0-423c-b967-f4ec2adc9b86-bg1c.png)
Whencommunicatingviatheparallel
port(refertoFigure14),the
previouslymentionedparametersare
notconsidered.Refertopage53to
configurethecommunication
parametersfortheprinter.The
valuesselectedmustbethesameas
thoseusedbythehostequipment
connectedtotheprinter.
Forserialandparallelpinoutand
technicalinformation,refertothe
Appendixonpage93.
CablingRequirements
Datacablesmustbefullyshieldedandfittedwithmetalormetalized
connectorshells.Shieldedcablesandconnectorsarerequiredtoprevent
radiationandreceptionofelectricalnoise.
Tominimizeelectricalnoisepickupinthecable:
n
Keepdatacablesasshortaspossible.
n
Donotbundlethedatacablestightlywiththepowercords.
n
Donottiethedatacablestopowerwireconduits.
NOTES:ZebraprinterscomplywithFCC“RulesandRegulations”,
Part15,SubpartJ,forClassAEquipment,usingfullyshielded
6’datacables.Useoflongercablesorunshieldedcablesmay
increaseradiatedemissionsabovetheClassAlimits.
RS-422andRS-485applicationsshouldusetwistedshielded
pairsasrecommendedintheAppendixoftheTA/EA.-485
Specification.
22 ZebraXiIII-SeriesUser’sGuide
10’maximum
25-pin
male
ComputerPrinter
36-pin
male
PC
25-pin
female
Figure14