Oven Door Microswitch (C Model)
WARNING: Always perform the Electrical Lockout/Tagout procedure before removing
any sheet metal panels or attempting to service this equipment. Failure to comply with
this procedure can cause property damage, injury or death.
1. Perform the CONTROL PANEL removal procedure for the convection oven.
2. Tag and disconnect the two (2) electrical wires to the oven door microswitch.
3. Remove the two screws, lock washers and nuts securing the microswitch to the mount
bracket.
4. Reverse the procedure to install the oven door microswitch.
5. Reverse the CONTROL PANEL removal procedure to install the control panel.
6. Test the oven to verify proper operation.
Figure 29: Oven Door Microswitch Removal
SERVICE PROCEDURE AND ADJUSTMENTS
In order to provide maximum performance, proper operation, and insure the safety of the
operator, the oven should be serviced at least once a year by an authorized technician. If an
oven has not been in use or has been in storage for extended period, the unit should be
inspected by an authorized technician prior to reinstallation and/or operation.
WARNING: Certain procedures in this section require electrical tests or measurements
while power is applied to the unit. Exercise extreme caution at all times. If test points are
not easily accessible, disconnect power and follow Lockout/Tagout procedures, attach
test equipment and reapply power to test.
When troubleshooting, always reference the schematic and wiring diagrams to assist in isolating
the problem.