– 5 –
LOCATION
The range must be kept free and clear of combustible substances. The range, when installed, must
have minimum clearance of 6" at the sides and 6" at the back from combustible construction, and 0"
at the sides and 0" at the back from non-combustible construction.
The installation location must allow adequate clearances for servicing and proper operation. A
minimum front clearance of 40" is required.
The range must be installed so that the flow of combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion chamber must be provided. Make sure there
is an adequate supply of air in the room suitable for the amount of combustion gas feeding the burners.
Do not permit fans to blow directly at the range. Wherever possible, avoid open windows next to the
range. Avoid wall-type fans which create air cross currents within the room.
INSTALLATION CODES AND STANDARDS
Your Vulcan range must be installed in accordance with:
1. State and local codes, or in the absence of local codes, with:
2. National Fuel Gas Code, ANSI-Z223.1 (latest edition), available from the American Gas Association,
Inc., 1515 Wilson Blvd., Arlington, VA 22209.
3. National Electrical Code ANSI/NFPA-70 (latest edition).
RANGES INSTALLED WITH CASTERS
Fig. 2
For ranges equipped with casters, the installation shall be
made with a connector that complies with the Standard for
Connectors for Movable Gas Appliances, ANSI Z21.69
(latest edition), and a quick-disconnect device that complies
with the Standard for Quick-Disconnect Devices for Use
With Gas Fuel, ANSI Z21.41 (latest edition). Provide a gas
line strain relief to limit movement of the range without
depending on the connector and any quick-disconnect
device or its associated piping to limit the range movement.
Attach the strain relief to the rear of the range (Fig. 2).
Should it be necessary to disconnect the gas line strain
relief, turn off the gas supply before disconnection.
Reconnect this restraint before turning the gas supply on
and returning the range to its installation position.
When this range is installed with casters, it must be installed with the casters supplied.
PL-51219
CONNECT GAS LINE
STRAIN
RELIEF HERE