3. Installation 3.1 Unpacking, Handling and Storage
Step 1
Refer to the pump weights guide (chapter 5) before selecting and using any lifting gear. The drawings show how the pump should
be lifted.
Ensure that lifting equipment is correctly rated and used within these limits.
Bareshaft pump
Pump with drive unit
Step 2
On receipt always:
- Check the delivery note against the goods received.
- If motorised, check that the drive instructions are available.
- Inspect the packing for signs of damage in transit.
- Carefully remove the packing away from the pump.
- Inspect the pump for any visible signs of damage.
- Clean away the packing from the pump port connections.
- Report any damage immediately to the carrier.
Step 3
After receipt and inspection, if the pump is not to be installed immediately, the pump should be repacked and placed in suitable
storage. The following points should be noted:
- Plastic or gasket type port covers should be left in place.
- Pumps received wrapped with corrosion inhibiting treatment material should have wrapping replaced.
- A clean, dry storage location free from vibration should be selected. If a moist or dusty atmosphere is used for storage, further
protect the pump or unit with a suitable cover.
- Rotate the pump/pump unit by hand weekly, to prevent bearing damage.