Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0846
A. Fuel Conversion
• Make sure the appliance is compatible with available
gas types.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies speci ed
and approved parts.
11
Gas Information
• Turn control knob on the valve to OFF position.
• Remove glass assembly (see Figure 14.A)
• (Remove logs, grate, and ember bed if already
installed.)
• Remove 2 screws holding pilot bracket to burner. See
Figure 11.1.
Kit contents:
Pilot injector #35
Burner ori ce
Red pin
Conversion Label
Tools Required:
#2 phillips screwdriver
Straight screwdriver
5/32 allen wrench
3/8 & 11/16 wrenches
Figure 11.1 Remove Pilot Screws
• Remove 4 screws holding Burner in place and remove
burner. See Figure 11.2.
Figure 11.2 Remove Burner Screws
• Using a 3/8 wrench, unscrew and remove rear ori ce
and discard. See Figure 11.3.
Figure 11.3 Remove Burner Ori¿ ce
• Unscrew and remove front ori ce #46 and install in
rear.
• Install new ori ce #56 in front.
• Open air shutters to fully open. See Figure 11.4.
• Replace burner and screws holding it in place.
Figure 11.4 Adjusting Air Shutter
Note: Gas conversions should only be performed by a
quali ed service person, and/or where required by state
and local codes, licensed installer/service technician. In
the Commonwealth of Massachusetts, installation must
be performed by a licensed plumber or gas tter.
Converting to LP Gas