DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-275status hardware-group
8
Field descriptions
status hardware-group
Summary information for the active or last hardware group test displays. This
display includes the number and percentage of tested maintenance objects, the
percentage of tests passed, failed, and aborted, the time elapsed since initiating
the hardware group test, the specific hardware group test command (see ‘‘
test
hardware-group’’ command) initiated, and the state (active/canceled/complete)
of the hardware-group test.
Data Ext/Sta Ext
for Stn DM
The data module extension number. The DTDM is an exception: the
connected station extension is shown.
Port/Channel
Number
The port location of the data module (cabinet-carrier-slot-circuit). If
the data module specified is a data channel, the channel number is
shown instead.
Service State
This entry displays the status of the data module; valid states are:
— In-service/idle
— The data module is present but not in use.
— In-service/active
— The data module is present and is in use.
—Out-of-service
— The data module has been removed from service
— Disconnected
— The data module no longer appears to be present
CF Destination Ext
This entry displays the call forwarding destination, if any, of the
station.
Maintenance Busy?
Whether maintenance is testing the object, "yes" or "no".
Connected Ports
Port locations to which the data module is connected
(cabinet-carrier-slot-circuit).
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status
hardware-group
print
Report sent to printer.
Examples:
status hardware-group
status hardware-group print
init
inads
craft
cust
rcust
bcms
browse
none none