Fig. 8
Built-under variants:
Fig. 9 for recess height 820 or 870 mm
A = Height of recess
B = Height of unit plinth
C = Height of unit door
D = Base height of cut-away unit plinth
Recess
height A
Height of unit
plinth B
Height of unit
door C
Base height of
unit plinth D
820 mm 100 mm 716 mm 100 mm
820 mm 170 mm 646 mm 100 mm
870 mm 150 mm 716 mm 150 mm
870 mm 220 mm 646 mm 150 mm
Note
u
Before assembling the door of the unit, make sure that the
admissable weight of the unit door is not exceeded.
u
Otherwise damage to the hinges and resultant malfunction
cannot be ruled out.
Model Max. weight of unit
door
UIK 10 kg
UIG 20 kg
2.3.1 Installing the appliance
u
Detach the connecting cable from the rear of the appli-
ance, removing the cable holder at the same time
because otherwise there will be vibratory noise!
u
Lay the connecting cable with
the help of a string in such a
way that the appliance can be
easily connected after fitting.
Fig. 10
u
Extend the front height-adjustable feet in preparation,
depending on recess height.
Slide in and align the appliance:
NOTICE
Risk of harm to flooring susceptible to damage!
u
Place a strip of cardboard under the height-adjustable feet,
approx. 10 cm x 60 cm, one at either side. Cut the strips out
of the packaging. For opening heights less than 826 mm,
use strips of a firm but thin material.
u
After the appliance has been slid in, remove the strips.
u
Slide the appliance into the
recess and align the front
edges of the hinges so that
they are flush with the side
wall of the unit.
Fig. 11
w
The distance between the front edge of the side wall of the
unit to the appliance body is 41.5 mm all the way round.
(Allow for door stop components, such as knobs and sealing
lips.)
For units with door stop components (knobs, sealing
lips etc.):
u
Allow for the extra distance (depth of the door stop compo-
nents): Allow the hinges to protrude by the additional
distance required.
Putting into operation
5