Table 2. Critical remote alerts
Alphanumeric
pager code
Alphanumeric
recovery code Event Action
00 50 Temperature
irregularity
Generates an alert if any of the monitored temperatures are
outside critical threshold values. To view the threshold
values, click the temperature readings on the System Health
page. If a critical temperature condition is detected, the
server shuts down and turns off, regardless of the alert
notification setting.
01 51 Voltage
irregularity
Generates an alert if the voltages of any of the monitored
power supplies fall outside their specified operational ranges.
To view the operational ranges, click the voltage readings on
the System Health page. If a critical voltage condition is
detected, the server shuts down and turns off, regardless of
the alert notification setting.
02 52 Tampering Generates an alert if physical intrusion of the server is
detected. Tamper monitoring is not available on some
servers, in which case this setting is ignored.
03 53 Multiple fan
failure
Generates an alert if two or more of the cooling fans in the
server fail.
04 54 Power failure Generates an alert if any of the server power supplies fail.
05 55 Hard disk drive
failure
Generates an alert if one or more of the hard disk drives in
the server fail.
06 56 VRM failure Generates an alert if one or more voltage regulator modules
(VRMs) fail. This setting is ignored for servers without VRMs.
07-09 Reserved for future use.
Warning alerts
Warning alerts are generated for events that might progress to a critical
level. If the Select all warning alerts check box is selected, an alert
can be sent for any warning alert.
Table 3. Warning remote alerts
Alphanumeric
pager code
Alphanumeric
recovery code Event Action
10 60 Redundant power
supply failure
Generates an alert if a redundant power supply fails.
11 61 Single fan failure Generates an alert if one fan fails.
12 62 Temperature
irregularity
Generates an alert if any monitored temperatures are
outside the warning threshold values. To access these
temperature threshold values, click the temperature
readings on the System Health page. Unlike the critical
temperature event, this event will not initiate a server
shutdown.
13 63 Voltage
irregularity
Generates an alert if any monitored voltages are outside the
warning threshold values. To access these voltage range
values, click the voltage readings on the System Health
page. Unlike the critical voltage event, this event will not
initiate an automatic server shutdown.
14 - 19 Reserved for future use.
28 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User’s Guide