Trakker Antares 243X Hand-Held Terminal User’s Manual
nugget
39
2-12
For more information about upgrading firmware, see Chapter 2 in the 2400 Family
system manual. For more information about downloading applications, see “How to
Download and Run Applications” in Chapter 3 of the 2400 Family system manual.
To clone configuration parameters and applications
1.
Make sure the server terminal’s configuration is saved in flash memory by scanning
this bar code:
Save Configuration in Flash Memory
*.+1*
*.+1*
2.
Load all applications and files to clone on the server terminal’s C drive.
3.
Run the clone application on the server unit.
a.
From the Main Menu, select System Menu, and then select Clone Unit.
b.
Select Server.
4.
Connect COM1 on the server terminal to COM1 on the client terminal using the
cloning cable (Part No. 216-909-001) (sold and ordered separately).
The cloning process automatically begins once you connect the terminals. The
client terminal lists the applications when cloning is complete.
5.
On the server terminal, press to exit. You can also configure another terminal
by connecting it to the server terminal.
Configuring Drives and Memory on the Terminal
The 243X come with a 750K flash drive (C), 512K RAM reserved for applications, and
an additional 2MB extended flash memory. You can customize the terminal to your
needs by configuring
•
up to 256K of the 512K RAM as a RAM drive.
•
the additional 2MB flash memory to either store double-byte fonts or to use as a
2MB drive.
Configuring the RAM Drive
The 243X has a total of 512K RAM for the application execution space. You can
configure up to 256K of the total 512K application execution space as a RAM drive. If
the RAM drive is configured, your application execution space is reduced by the