Technical Data
312394V 73
Technical Data
Metering Pump Effective Area .....................
80 to 960 mm
2
(0.124 to 1.49 in.
2
) per side
Small Air Cylinder Effective Area ...................
4560 mm
2
(7.07 in.
2
)
Large Air Cylinder Effective Area ..................
10260 mm
2
(15.9 in.
2
)
Maximum Stroke Length ......................... 38.1 mm (1.50 in.)
Minimum Stroke Length ......................... 5.8mm(0.23 in.)
Volume per Cycle ..............................
2 to 70 cc (0.12 to 4.3 in.
3
)
Pump Cycles per 1 L (0.26 gal) .................... 14.3 to 500 cycles (varies by piston size)
Ratios (fixed) .................................. 1:1to12:1 (depending upon cylinders selected)
Maximum Fluid Working Pressure .................. 3000 psi (20.7 MPa, 207 bar)
Maximum Air Input Pressure ...................... 100psi(0.7 MPa, 7 bar)
Maximum Cycle Rate ........................... 30cpm
Maximum Operating Temperature .................. 70°C (160°F), nylon pistons 50°C (120°F) UHMWPE pis-
tons or PE Tanks
Air Inlet Size .................................. 1/4NPTfemale
Pump Fluid Outlet Size .......................... -03, -04, -06, -08 or –12 JIC fittings for 3/16 in. (4.8 mm),
1/4 in. (6.4 mm), 3/8 in. (9.5 mm), 1/2 in. (12.7 mm),
3/4 in. (19.1 mm) hoses
Wetted Parts ..................................
303/304, 17-4 PH, hard chrome, Chromex
™
, carbide,
Chemical Resistant O-rings, PTFE, nylon, UHMWPE
Weight ....................................... 55kg(120 lb) typical with two 7.5 L tanks
150 kg (330 lb) typical with two 60 L tanks
Sound Pressure Level (at typical operator station for
machine mounted Dispense Valve ................. 82dBA
Compressed Air ................................ Less than 10 scfm typical (varies with cycle times)
Electrical Power ................................ • 100-240 V 50/60Hz, 1 phase for machine – 80 Watts
• 208-240V 50/60Hz, 1 phase for heat – 11 kW max
• 120 or 240 VAC 50/60Hz 1 phase for on-board agita-
tors, 80 Watts
• 240 VAC 50/60Hz 1 phase for off-board agitators,
600 Watts