WARNING:
If fireplace has glass doors, never operate this
heater with glass doors closed. If you operate
heater with doors closed, heat buildup inside fire-
place will cause glass to burst. Make sure there are
no obstructions across opening of fireplace.
You must operate this heater with a fireplace screen
in place. Make sure fireplace screen is closed
before running heater.
NOTICE: During initial operation of new heater, burn-
ing logs will give off a paper-burning smell. Orange
flame will also be present. Open damper or window to
vent smell. This will only last a few hours.
LIGHTING
INSTRUCTIONS
INSTALLATION
Continued
INSTALLATION
Installing Logs (Cont.)
OPERATING HEATER (MANUALLY-CONTROLLED MODELS)
For Your Safety Read Before Lighting
Lighting Instructions
Figure 21 - Front and Rear Log Placement (Thermostat Models)
Figure 22 - Front Log Placement (Thermostat Models)
OPERATING HEATER
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire de-
partment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
FOR YOUR SAFETY
READ BEFORE LIGHTING
MANUALLY-CONTROLLED MODELS
Thermostat Models (CDL)
1. Place rear log on 2 pins on rear brackets (see Figure 21).
2. Place front log on grate fingers and over pins of rear log as
shown in see Figure 21.
3. Place control cover log onto two pins on front log assuring the
cover log seats into cutout section of front log (see Figure 22).
4. Place crossover log on pins on rear and middle log (see
Figure 22).
Rear and
Middle Log
Front Log
Crossover
Log
Cover Log