10
Upper Line 1st Digit for TC Warnings
0 1 2 3 4 5 6 7 8 9 A b C d E F Warning Remedy
• • • • • • • • no valid TC frame rate set correct TC frame rate
or switch off TC
• • • • • • • • no meaning on 416 N/A
• • • • • • • • no meaning on 416 N/A
• • • • • • • • the last take has no briey depress the „PHASE“-button,
or intermittent TC or reshoot
Upper Line 2nd Digit for TC Warnings
0 1 2 3 4 5 6 7 8 9 A b C d E F Warning Remedy
• • • • • • • • more than 8 hours reset TC
since TC was last set
• • • • • • • • TCS values not valid reset TCS value
• • • • • • • • ESU frame rate check ESU frame rate
outside TC range (display Mode 1)
and TC generator frame rate
(Mode 4);
max. allowable difference is 1 %
• • • • • • • • no TC with variable speed switch off variable speed accessory
or TC as TC-operation with variable
speed is not possible
Timecode