Controls Configuration & Adjustments...
Microprocessor Factory Default Settings
Level –1 and Level-2 Default Settings
Menu Code Description Default Value Range
Level-1 [CF1] Celsius/Fahrenheit 1 0 / 1
Level-1 [ULC] User Lock Code 0 0 / 1
Level-1 [ELC] Enter Lock Code 0 00-99
Level-1 [CFO] Call / Flex 0 0 / 1 / 2
Level-1 [LOC] Service Lock Code 50 00-99
Mode Key Pad Operating Mode OFF
For Heat Only
OFF/HEAT
For Heat & Cool
OFF, HEA,
COO, ACH
Thermostat Key Pad Thermostat Settings Pool & Spa OFF 45
o
F – 104
o
F
Level-2 [dEL] 4-minute Delay on Make 1
0 / 1
Level-2 [JAO] External Controller Interface 0 0 / 2 / 3
Level-2 [FS2]
Flow Switch / Auto T-Stat
Switching
0 0 / 1
Level-2 [tSC] Water Sensor Calibration
Factory
Calibrated
+10
o
to –10
o
of
displayed value
Level-2 [dSC] Defrost Sensor Calibration
Factory
Calibrated
+10
o
to –10
o
of
displayed value
Level-2 [dBS] Spa Dead Band Differential 1
o
1
o
to 5
o
Level-2 [dBS] Spa Dead Band Differential 1
o
1
o
to 5
o
Microprocessor Level-2 Set Up & Calibration Codes
Service Adjustable Parameters
Code Description Factory Setting Range
[LOC] Service Lock Code 50 00-99
[dEL] 4-minute Delay on Make 1 0 / 1
[JAO] External Controller Interface 0 0 / 2 / 3
[FS2] Flow Switch/Auto T-Stat Switching 0 0 / 1
[tSC] Water Sensor Calibration Factory Calibrated +10
o
to –10
o
of display
[dSC] Defrost Sensor Calibration Factory Calibrated +10
o
to –10
o
of display
[dBS] Spa Dead Band Differential 1
o
1
o
to 5
o
[dBP] Pool Dead Band Differential 1
o
1
o
to 5
o