Zanussi ZWH3125 Washer User Manual


 
48
Water inlet
There should be a COLD WATER tap near the
washing machine with a screwing on
connection pipe of 3/4" for the water supply, a
sink, a wash basin or a drainage system in the
wall.
Previously check if:
- it is not a hot water tap.
- the running water is clean. If not, run off a
reasonable amount of water to flush out any
debris that may have collected in the pipes.
Have the permanent drainage system in the
wall checked by a plumber.
1. Connect the hose to a tap with a 3/4”
thread. Always use the hose supplied with
the appliance. The inlet hose must not be
lengthened. If it is too short and you do not
wish to move the tap, you will have to
purchase a new, longer hose specially
designed for this type of use.
NOTE
Installation should
comply with local
water authority and
building regulations’
requirements.
2. If necessary turn the hose adequately by
unscrewing the nut at the rear of the
appliance. Now tighten the nut anew to
avoid leaks. (Open the tap and assure that
it does not leak and close it again.)
The appliance must be connected to a cold
water supply.
A minimum water pressure of 0.05 MPa (0.5
bar) is required for safe operation of the
appliance.
If you cannot make the cold water connection
direct from the rising mains, you may be able
to operate the appliance from your cold water
storage system.
There should be a minimum distance of 5.02m
(16.5 ft) between the appliance’s inlet and the
bottom of the water storage tank.
Electrical connection
Any electrical work required to install this
appliance should be carried out by a qualified
electrician or competent person.
WARNING!
This appliance must be earthed.
The manufacturer declines any liability
should this safety measure not be
observed.
Before switching on, make sure the electricity
supply voltage is the same as that indicated
on the appliance’s rating plate.
IMPORTANT!
Information on the electrical connection is
given on the rating plate on the inner edge
of the appliance door.
The appliance is supplied with a 13amp plug
fitted. In the event of having to change the
fuse in the plug supplied, a 13amp ASTA
approved (BS1363/A) fuse must be used.
Should the plug need to be replaced for any
reason, proceed as described below.
126.2936.39…ZWH3105-3125.qxd 24/10/08 09:01 Página 48