Whirlpool 8533582 Clothes Dryer User Manual


 
9
Electrical Connection Options
*If local codes do not permit the connection of a frame-grounding
conductor to the neutral wire, go to “Optional
3-wire Connection” section.
4-wire connection: Power supply cord
IMPORTANT:
A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
1.
Remove center terminal block screw.
2.
Remove appliance ground wire (green with yellow stripes)
from external ground conductor screw. Fasten it under center,
silver-colored terminal block screw.
3.
Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
4.
Connect neutral wire (white or center wire) of power supply
cord under center screw of the terminal block.
5.
Connect the other wires to outer terminal block screws.
Tighten screws.
6.
Tighten strain relief screws.
7.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
4-wire connection: Direct wire
IMPORTANT:
A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5 in. (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5 in. (12.7 cm). Cut 1
¹⁄₂
in. (3.8 cm) from 3
remaining wires. Strip insulation back 1 in. (2.5 cm). Shape ends
of wires into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example
below.
1.
Remove center terminal block screw.
2.
Remove appliance ground wire (green with yellow stripes)
from external ground conductor screw. Fasten it under center,
silver-colored terminal block screw.
If your home has: And you will be
connecting to:
Go to Section
4-wire receptacle
(NEMA Type 14-30R)
A UL listed, 120/
240 volt
minimum, 30
amp, dryer
power supply
cord*
4-wire connection:
Power supply cord
4-wire direct A fused
disconnect or
circuit breaker
box*
4-wire connection:
Direct Wire
3-wire receptacle
(NEMA type 10-30R)
A UL listed, 120/
240 volt
minimum, 30
amp., dryer
power supply
cord*
3-wire connection:
Power supply cord
3-wire direct A fused
disconnect or
circuit breaker
box*
3-wire connection:
Direct Wire
1. 4-wire receptacle (NEMA type 14-30R)
2. 4-prong plug
3. Ground prong
4. Neutral prong
5. Spade terminals with upturned ends
6. ¾ in. (1.9 cm) UL listed strain relief
7. Ring terminals
1. External ground conductor screw - Dotted line
shows position of NEUTRAL ground wirebefore
being moved to center terminalblock screw
2. Center silver-colored terminal block screw
3. Green/yellow wire of harness
5"
(12.7 cm)
3 / "
(8.9 cm)
1
2
1
2
3
4
6
5
7
1
2
3
1. External ground conductor screw
2. Green or bare copper wire of power supply cord
3.
³⁄₄
in. (1.9 cm) UL listed strain relief
4. Center silver-colored terminal block screw
5. Neutral grounding wire (green/yellow)
6. Neutral wire (white or center wire)
1
2
3
4
5
6